5.3 Programming Descriptions
5-43
[804]-[001]-[032] Wireless Device Serial Number
These sections are for manual enrollment of one-way wireless device serial numbers (ESN).
• See [804][101]-[116] for one-way and two-way wireless key enrollment.
• See [804][201]-[204] for two-way keypad enrollment.
• See [804][301]-[304] for two-way siren enrollment.
This is a 6-digit entry. For toggling entries between decimal and hexadecimal values, press [
].
[804][081] Wireless Supervisory Windows
This entry is used to program the length of time a wireless device must be absent from the system before a fault is generated. The wireless supervisory window is
calculated by multiplying the programmed value by 15 minutes.
Valid entries are 04 to 96 which correlates to 1 to 24 hours. The default value for North America is 96 (24 hours) and 08 (2 hours) for Europe.
[804][082]-[085] Zone Transmitter Supervision Options
Program these sections if the zone transmitter will be supervised. All zones are enabled for supervision by default.
[804][101]-[116] Wireless Key Serial Number
These sections are used to enter the wireless key serial numbers. This is an 8-digit hexadecimal entry. To toggle entries between decimal and hexadecimal values,
press [
]. Two-way wireless keys have 8-digit serial numbers, the existing one-way serial numbers have 6-digits. “00” must be added to the start of a 6-digit serial
number.
[804][141]-[156] Wireless Key Function Key Options
Up to 6 unique functions can be programmed for each wireless key. Each section requires four 2-digit entries. The following table describes each programmable
function.
Option Description
[1]
ON: Standard Door Chime Enabled. Traditional door chime tone found on other DSC keypads (6 quick beeps)
OFF: Standard Door Chime Disabled
[2]
ON: ‘Bing-Bong’ Door Chime Enabled
OFF: ‘Bing-Bong’ Door Chime Disabled
[3]
ON: ‘Ding-Dong’ Door Chime Enabled.
OFF: ‘Ding-Dong’ Chime Disabled.
[4]
ON: 4-second Alarm Tone Door Chime Enabled. The keypad/siren will sound a medium volume alarm signal for 4 seconds.
OFF: 4-second Alarm Tone Door Chime Disabled.
[5]-[8]
For Future Use
One-way Devices Two-way Devices
The first digit of a 6-digit serial number for one-way
devices identifies the type of device as indicated below:
The first digit of an 8-digit serial number for two-way devices is 2.
The second digit identifies the type of device as follows:
2
Door/Window Contact or Flood Sensor
20
Wireless Keypad
3
PIR or Glass Break Detector
21
Wireless Keypad with Proximity Tag Detector
4
Smoke Detector
22
Future Use
5
Panic Pendant
23
Wireless Indoor Siren
6
Wireless Keys
8
Carbon Monoxide Detector
24
Wireless Outdoor Siren
9 Wireless Keys 25
Wireless two-way Key
i
Leading 00s must be entered for one way wireless devices with six digit serial numbers (E.g. SN 234567 must be entered
as 00234567).
i
This timer may run the programmed time plus up to the number of minutes programmed in this section. For example, the European one-way default is
2 hours, but the actual time could be as long as 2 hours and 8 minutes. The North American one-way default is 24 hours, but the actual time could be
as long as 25 hours and 36 minutes.
UL
UL fire listings require a 4 Hr setting (4 Hrs = 16, 16x15 minutes)
i
DSC does NOT recommend supervision of panic pendants, because they may be removed from the premises.
Entry Description DSC Wireless Key
00
Null Key (Key Not Used) YES
03
Stay Arm YES
04
Awa y Arm YE S